Who's Online
There currently are 5958 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I want to give you a real heads-up for your desire to enable such people as I to acquire the information I need to maintain the older types of equipment such as this Akai HXA351W. You do a swell job with all the processes you have to perform so I can have a legible, thus usable
document which does not send me crazy trying to figure out the blurry text of a bad copy.
Very well done, Thomas.
;
This manual is very well presented and after printing out looks about as close to an original as I think you can get. The quality is second to none.
The content of the manual is comprehensive and I think it would be well suited to an audio repair professional which I'm not but I did find it very informative and helpful.
The cost of the manual is more than covered by the money I'll save when I change the keep memory battery now I have the relavant info.
Very pleased with my purchase and can recommend it wholeheartedly as I can other manuals I've downloaded from this site.
Regards
Limey Alex
;
Complete manual including mechanical part in good pdf quality. Shaded greys of the pcb due to pdf not perfect but usable.
;
Nice pdf file of the manual sent promptly. Thanks.
;
Complete MFG Service Manual at a good price FAST !
ELECTRICAL ADJUSTMENTS
3. PURITY AND CONVERGENCE ADJUSTMENTS
NOTE 1. Turn the unit on and let it warm up for at least 30 minutes before performing the following adjustments. 2. Place the CRT surface facing east or west to reduce the terrestrial magnetism. 3. Turn ON the unit and demagnetize with a Degauss Coil. 3-1: STATIC CONVERGENCE (ROUGH ADJUSTMENT) 1. Tighten the screw for the magnet. Refer to the adjusted CRT for the position. (Refer to Fig. 3-1) If the deflection yoke and magnet are in one body, untighten the screw for the body. 2. Receive the green raster pattern from the color bar generator. 3. Slide the deflection yoke until it touches the funnel side of the CRT. 4. Adjust center of screen to green, with red and blue on the sides, using the pair of purity magnets. 5. Switch the color bar generator from the green raster pattern to the crosshatch pattern. 6. Combine red and blue of the 3 color crosshatch pattern on the center of the screen by adjusting the pair of 4 pole magnets. 7. Combine red/blue (magenta) and green by adjusting the pair of 6 pole magnets. 8. Adjust the crosshatch pattern to change to white by repeating steps 6 and 7. 3-2: PURITY NOTE Adjust after performing adjustments in section 3-1. 1. Receive the green raster pattern from color bar generator. 2. Adjust the pair of purity magnets to center the color on the screen. Adjust the pair of purity magnets so the color at the ends are equally wide. 3. Move the deflection yoke backward (to neck side) slowly, and stop it at the position when the whole screen is green. 4. Confirm red and blue colors. 5. Adjust the slant of the deflection yoke while watching the screen, then tighten the fixing screw. DEFLECTION YOKE DEFLECTION YOKE SCREW MAGNET SCREW 3-3: STATIC CONVERGENCE NOTE Adjust after performing adjustments in section 3-2. 1. Receive the crosshatch pattern from the color bar generator. 2. Combine red and blue of the 3 color crosshatch pattern on the center of the screen by adjusting the pair of 4 pole magnets. 3. Combine red/blue (magenta) and green by adjusting the pair of 6 pole magnets. 3-4: DYNAMIC CONVERGENCE NOTE Adjust after performing adjustments in section 3-3. 1. Adjust the differences around the screen by moving the deflection yoke upward/downward and right/left. (Refer to Fig. 3-2-a) 2. Insert three wedges between the deflection yoke and CRT funnel to fix the deflection yoke. (Refer to Fig. 3-2-b) RGB R G B RGB
R G B RIGHT/LEFT SLANT
UPWARD/DOWNWARD SLANT
Fig. 3-2-a
WEDGE
WEDGE
WEDGE WEDGE POSITION Fig. 3-2-b
PURITY MAGNETS 6 POLE MAGNETS 4 POLE MAGNETS Fig. 3-1