Who's Online
There currently are 5747 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This manual is complete and very readable.It was a great help for my two ICF5800L.The first one had the dial cord broken,and without the service manual it is impossible to replace it.Thank.Olivier.
;
This is a top quality manual. You couldn't get better if you had the original and scanned it yourself. Best price on the net as well. Diagrams are clear and complete, text is sharp and easy to read. Granted you don't get the manual the second you click pay, but the few hours you have to wait for it to be available for download isn't a problem at all. This is a very reliable company.
Very VERY pleased with the product, and will buy others. Thanks!
;
In a word AWESOME.
I never expected the quality and abundant content that I got with this manual. Everything you'd ever want to know from a service perspective is found in this manual, along with... as a bonus, operating instructions on how to use the unit. WOW. Very impressed with the quality of the manual. You won't be disappointed if you're looking for the EVS900 service manual.
;
I thank Owen-Manuals.com for the wonderful service rendered to me, and this manual which I purchased helped me a lot in servicing my Denon System, which was lying in a dead state.
Thanks Owner-Manual.com
;
I purchased this manual to repair my Teac set and with the support of this manual I rectified the problem.
Thanks Owner-Manuals.com
3. The base and handset cannot be connected.
Check whether the base NG is able to set in the test mode 8. OK Check the TX POWER NG and the TX FREQUENCY on the base unit. OK Set the base in the test NG mode 10, check whether deviation of the TX data is app. 9.0 kHz Dev. OK Check whether there is a NG 250 Hz data waveform at MOD of RF unit. OK Check base RF unit. Check RT3, R76, R91, R49, C129, C122, C33 and C52. Check base RF unit. Check IC4 and its peripheral circuit.
Set the base in the test NG mode 13, 902.952467MHz (250 Hz �8 kHz Dev.) 1mV output signal from RF test point is applied. Does the CHARGE LED light? OK
Check whether there is a NG 250 Hz data waveform at RT2 AF test point. OK
Check IC3, Q1 and their NG peripheral circuit. OK
Check base RF unit.
Check whether there is a NG 250 Hz data waveform at the Q2 collector. OK Check whether there is a NG 250 Hz data waveform at pin 64 of IC4. OK Check IC4 and its peripheral circuit.
Check RT2, Q2 and their peripheral circuit.
Check R27, R171, R172, IC1 and their peripheral circuit.
Check whether the NG handset is able to set in the test mode 1. OK Check the TX POWER NG and the TX FREQUENCY on the handset unit. OK A
Check IC603 and its peripheral circuit.
Check handset RF unit.